J Korean Soc Plast Reconstr Surg Search

CLOSE


Journal of the Korean Society of Plastic and Reconstructive Surgeons 2005;32(1):5-11.
Published online January 1, 2005.
An Effects of a New PGE1: Lipo-AS013 on Blood Flow and Survival of Skin Flap.
Chul Hwan Seul, Jong Woo Choi, Yong Hoon Chi, Kwan Chul Tark
1Department of Institute for Human Tissue Restoration, Yonsei University College of Medicine, Seoul, Korea.
2Department of Plastic and Reconstructive Surgery, Yonsei University College of Medicine, Seoul, Korea. kctark@yumc.yonsei.ac.kr
Abstract
Prostaglandin E1(PGE1) is known to have various physiological action such as vasodilatation, decrease of blood pressure, angiogenesis, inhibition of platelet aggregation and so forth. PGE1 has been developed in many different formulations in order to overcome its chemical instability and deactivation in the lungs when administered parenterally. Lipo-AS013 is a potent drug with higher chemical stability and greater vascular wall targeting than others. The study was done on 3x10 cm model flap of dorsal skin of Sprague-Dawley rats and the flap perfusion survival were observed and documented. The flap treated with Lipo-AS013 beforehand was given intravenously Sodium fluorescein 10 minutes later, and then Percent Dye Fluorescence Index(% DFI) was calculated. The results were compared to a control group and the group administered locally epinephrine. In the control group, the % DFI and flap survival rate increased from 54.1+/-6.7 to 65.0+/-2.6(p<0.01) while in Lipo-AS013 group from 55.3+/-2.2 to 67.4+/-1.9(p<0.01), respectively. In the epinephrine group, the % DFI(p<0.05) and flap survival rate(p<0.001) decreased. In the both epinephrine and Lipo-AS013 group Percent DFI and flap survival rate are comparable with the control group. The result indicates that the potent Lipo-AS013 enhances the blood flow and flap survival. This highly potent Lipo-AS013 may have targeting ability and accumulate PGE1 onto the vascular walls. A quantitative analysis of fluorescence on the skin surface is a reliable tool to measure the blood perfusion into an ischemic flap and its viability. Further comparative study with conventional PGE1 and Lipo-PGE1 is needed in order to clarify the action and efficiency of Lipo-AS013.
Keywords: PGE1; Lipo-AS013; Dye fluorescence index; Flap survival; Blood flow of flap
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1,247 View
  • 0 Download

The Effect of Melatonin on the Random Flap Survival in the Rat.2008 November;35(6)

The Effect of Duration of Lipo-PGE1 Administration on Flap Survival in a Rat TRAM Model.2002 March;29(2)

The Effects of Time Dependent Lipo-PGE1 Administration on Survival of a TRAM Flap in the Rat.2004 May;31(3)

Effect of prefabrication on the survival of venous island flap.1998 April;25(3)

Effect of Hyperbaric Oxygen & Allopurinol on the Survival of Irradiated Rat Skin Flap.1999 July;26(4)



ABOUT
ARTICLE & SPECIALITY
Article category

Browse all articles >

Speciality

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-2003, Lotte Castle President, 109, Mapodaero, Mapo-gu, Seoul 04146, Korea
E-mail: apsedit@gmail.com                

Copyright © 2024 by Korean Society of Plastic and Reconstructive Surgeons.

Developed in M2PI

Close layer
prev next