J Korean Soc Plast Reconstr Surg Search

CLOSE


Journal of the Korean Society of Plastic and Reconstructive Surgeons 2011;38(4):458-464.
Published online July 1, 2011.
Treatment of Metacarpal Bone Fracture Using Biodegradable Plates and Screws.
Jeong Mok Cho, Seok Chan Eun, Rong Min Baek
Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine, Korea. sceun@snubh.org
Abstract
PURPOSE
Metacarpal fractures are common hand injury that may require operative intervention to ensure adequate reduction and stabilization. Traditionally, titanium miniplate was used for rigid fixation of bone fractures. However, the use of permanent plate lends itself to multiple complications such as infection, exposure of the hardware, tendon adhesions, tendon rupture, prolonged pain, bony atrophy and osteoporosis (stress shielding), metal sensitization, and palpation under the skin. This study evaluated the usefulness and stability of biodegradable plates and screws for treatment of metacarpal bone fractures. METHODS: There was 17 patients who had surgery for metacarpal bone fracture from April 2007 to June 2010. All patients had open reduction and internal fixation. We used absorbable plates and screws (Inion CPS(R)) for internal fixation. Postoperative results were assessed with x-ray. Stability of plates and screws, healing process and its complications were observed by clinical and radiographic assessment.
RESULTS
All patients were successfully reduced of bone fracture, and fixations with absorbable plates and screws were stable. The mean follow up period was 7.1 months. 2 patients complained postoperative pain, but they were relieved with analgesics. All patients experienced transient stiffness, but they were relieved with active assistive range of motion after removal of splint. No patients suffered complications which could be occurred by using metallic plate.
CONCLUSION
There was no critical complications such as re-fracture or nonunion among patients. No patients suffered side effects related with metallic implants. Biodegradable implants can offer clinically stable and attractive alternative to metallic implants to stabilize metacarpal bone fractures in the hand.
Keywords: Metacarpal bones; Fracture fixation; Absorbable implants
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1,321 View
  • 0 Download

Treatment of Nasal Bone Fracture with Reverse U-Shaped Silicone Sheet.2009 March;36(2)

Tip Plasty using Biodegradable Plate as a Columella Strut.2010 May;37(3)

The Treatment of Pressure Sore Using Hydrogel and Hydrocolloid Dressing.2005 November;32(6)

Treatment of Recurrent Ischial Pressure Sore Using Sclerotherapy with Absolute Ethanol.2006 September;33(5)

Treatment of Diabetic Mouse Wounds using Blood Bank Platelet Concentrates.2007 May;34(3)



ABOUT
ARTICLE & SPECIALITY
Article category

Browse all articles >

Speciality

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-2003, Lotte Castle President, 109, Mapodaero, Mapo-gu, Seoul 04146, Korea
E-mail: apsedit@gmail.com                

Copyright © 2024 by Korean Society of Plastic and Reconstructive Surgeons.

Developed in M2PI

Close layer
prev next