K-Wire Breakage During Metalware Removal Due to a Defective K-Wire Shaft
Seong Jae Hong, Hyun Jic Lee, Jin Young Kim, Su Rak Eo, Sang Hun Cho
Arch Plast Surg. 2013;40(5):655-657. Published online 2013 Sep 13 DOI: https://doi.org/10.5999/aps.2013.40.5.655
|
Citations to this article as recorded by
Intraoperative Kirschner Wire Breakage in a Pediatric Supracondylar Humerus Fracture
Gaurav Ardawatia, Ankit B Waghela, Ashish S Ranade
Cureus.2021;[Epub] CrossRef Broken Kirschner Wire in Distal Interphalangeal Joint Fixation: A Case Report
Kyung Jin Lee, Jung Hyun Park, Sung Hoon Koh, Dong Chul Lee, Si Young Roh, Jin Soo Kim
Archives of Hand and Microsurgery.2021; 26(3): 171. CrossRef Kirschner Wire Breakage during Removal Requiring Retrieval
Kai Yuen Wong, Rosalind Mole, Patrick Gillespie
Case Reports in Surgery.2016; 2016: 1. CrossRef The Efficacy of Transverse Fixation and Early Exercise in the Treatment of Fourth Metacarpal Bone Fractures
Suk-Ho Moon, Hak-Soo Kim, Sung-No Jung, Ho Kwon
Archives of Plastic Surgery.2016; 43(02): 189. CrossRef
|