J Korean Soc Plast Reconstr Surg Search

CLOSE


Journal of the Korean Society of Plastic and Reconstructive Surgeons 2004;31(1):28-33.
Published online January 1, 2004.
Problems of Expanded Polytetrafluoroethylene (Gore-Tex(R)) in Augmentation Rhinoplasty.
Soon Jae Yang, Jang Hyun Lee, Min Seong Tark
1Dr. Yang's Institute of Rhinoplasty, Korea. yangnose@yahoo.co.kr
2Department of Plastic and Reconstructive Surgery, College of Medicine, Soonchunhyang University, Seoul, Korea.
Abstract
Augmentation rhinoplasty is one of the most popular aesthetic procedures in Asians. Numerous alloplastic implants have been used, however alloplastic implants may cause many problems in nasal and perinasal areas because of thin soft tissue cover. For these reasons, an ideal implant should be nonpalpable, readily exchangeable and biocompatible. Among these alloplastic implants, Gore-Tex(R) is a polymer of carbon bound to fluorine composed of solid nodes connected by very fine fibers. It has been reported that this material become permeated and surrounded by mature connective tissue, forming a strong supporting envelop for the material, yet the implant is easily removed because of limited tissue ingrowth. Since it's development, Gore-Tex(R) has found many applications in the field of facial plastic and reconstructive surgery. From November, 2001 to December, 2002, Gore-Tex(R) implants were removed from 17 patients due to several problems such as; decreased dorsal height, tip deformity, chronic inflammation. The implants were very hard to remove and coinciding injury of the surrounding tissue were inevitable. An analysis of the length and thickness changes in these removed implants was made. The results showed, decrease in length and thickness with a volume loss averaging, 46.3% in 45x4.0mm implants, 49.3% in 50x5.0mm implants. In view of the experiences of 17 cases of Gore-Tex(R) implants in rhinoplasty, we have concluded that Gore-Tex(R) implants were structurally unstable, fibrovascular tissue ingrowth into pores were minimal, the implants were very hard to remove and the implants caused a postoperative volume reduction. Therefore, Gore-Tex(R) use in augmentation rhinoplasty should be approached with caution.
Keywords: Expanded Polytetrafluoroethylene(Gore-Tex(R)); Rhinoplasty
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1,416 View
  • 0 Download

Experience with use of Expanded Polytetrafluoroethylene(Gore-tex(R)) in Cosmetic Facial Surgery.2003 January;30(1)

A Clinical Experience with the Use of Gore-Tex Implant in Augmentation Rhinoplasty.2004 January;31(1)



ABOUT
ARTICLE & SPECIALITY
Article category

Browse all articles >

Speciality

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-2003, Lotte Castle President, 109, Mapodaero, Mapo-gu, Seoul 04146, Korea
E-mail: apsedit@gmail.com                

Copyright © 2024 by Korean Society of Plastic and Reconstructive Surgeons.

Developed in M2PI

Close layer
prev next