J Korean Soc Plast Reconstr Surg Search

CLOSE


Journal of the Korean Society of Plastic and Reconstructive Surgeons 2002;29(4):302-310.
Published online July 1, 2002.
Utility of Laser Doppler Flowmetry in Postoperative Monitoring of Free Flap.
Jeong Tae Kim
Department of Plastic & Reconstructive Surgery, College of Medicine Dong-A University, Busan, Korea. jtkim@ donga.ac.kr
Abstract
Continuous observation based on the operator's clinical experience is impractical in monitoring free flap and the success rate of flap can be increased with the adjunctive monitoring system such as laser Doppler flowmetry. The author tried to establish the objective critical point to analyze the data in the postoperative period in microsurgical reconstruction. In this study, laser Doppler flowmetry(Periflux 4001 Master , Sweden) was used continuously for flap monitoring from the recovery room; every hour for 24hours, every 2 hours in the next 24 hours and every 3 - 6hours thereafter until the 7th day. Among 43 cases performed, 4 patients suffered from postoperative vascular insufficiency and they were decided to follow the exploration or salvage procedure. The value may be recorded at most 3.0 even when the tissue sufferes without flow due to its highly sensitive system, and it is quite reliable for flap survival if the initial value is above 3.0 with increasing trend. If the flow value persists below 3.0 continuously or show a plateau, vascular compromise can be doubted. Initial plateau or decline curve was caused by flap swelling and could be detected in 2 postoperative periods such as early (2-24hour) and /or late (26 -116 hour) period. Its decline was maximally up to 31.5% and this decline was more commonly observed in perforator- based free flap than others. However, its appearance and duration was quite unexpected especially in small free flap due to skin tension after suture. In conclusion, the laser Doppler flowmetry is a valuable adjunctive system in flap monitoring after operation by observing the trend in perfusion value.
Keywords: Laser Doppler Flowmetry; Flap monitoring
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1,134 View
  • 0 Download

Revision of Unfavorable Double Eyelid Operation by Repositioning of Preaponeurotic Fat.2000 March;27(2)



ABOUT
ARTICLE & SPECIALITY
Article category

Browse all articles >

Speciality

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-2003, Lotte Castle President, 109, Mapodaero, Mapo-gu, Seoul 04146, Korea
E-mail: apsedit@gmail.com                

Copyright © 2024 by Korean Society of Plastic and Reconstructive Surgeons.

Developed in M2PI

Close layer
prev next