PURPOSE
Augmentation mammoplasty by cohesive silicone gel implant is becoming more popular nowadays. Many types of complications have been reported, such as hematoma, seroma, infection, capsular contracture and etc. But there were no report of deep vein thrombosis(DVT) after augmentation mammoplasty in Korea. The authors experienced one case of DVT after augmentation mammoplasty using a cohesive silicone gel implant. METHODS: A 38-year-old woman with breast cancer underwent reconstruction by tissue expander and augmentation mammoplasty by cohesive silicone gel implant, and exchange of expander to cohesive silicone gel implant. The operation was finished without any complicating event. On 4th day after the operation, the patient complained of intermittent right lower leg pain. By doppler ultrasonography, the patient was diagnosed with acute venous thrombosis of the popliteal vein, posterior tibial vein and peroneal vein.
RESULTS
Intravenous heparinization and oral warfarin were started immediately and elastic compression stocking was applied. Intravenous heparinization was continued until INR(blood coagulation unit) reached to target levels. The patient was discharged on 11th day of operation with oral warfarin. Other complication has not been reported after 10 weeks of operation.
CONCLUSION
To our knowledge, this is the first report of DVT after silicone implant based breast augmentation.
Keywords: Deep vein thrombosis; Augmentation mammoplasty; Pulmonary embolism
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1,421 View
  • 0 Download

Capsular Flaps for Correcting Implant Palpability in Secondary Augmentation Mammoplasty.2009 November;36(6)

Rupture and Intrapleural Migration of a Cohesive Silicone Gel Implant after Augmentation Mammoplasty: A Case Report.2011 May;38(3)

Rupture of silicone gel prosthesis after augmentation mammoplasty.1991 January;18(1)



ABOUT
ARTICLE & SPECIALITY
Article category

Browse all articles >

Speciality

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-2003, Lotte Castle President, 109, Mapodaero, Mapo-gu, Seoul 04146, Korea
E-mail: apsedit@gmail.com                

Copyright © 2024 by Korean Society of Plastic and Reconstructive Surgeons.

Developed in M2PI

Close layer
prev next