J Korean Soc Plast Reconstr Surg Search

CLOSE


Journal of the Korean Society of Plastic and Reconstructive Surgeons 2010;37(4):385-390.
Published online July 1, 2010.
Usefulness of High-Resolution Ultrasonography after Foreign Body Injection on Aesthetic Plastic Surgery.
Eung Yeol Ko, Ha Min Sung, Geon Cho, Young Kyu Park, Kyoung Seok Tak, In Suck Suh, Ik Yang
1Department of Plastic and Reconstructive Surgery, Kangnam Sacred Heart Hospital, Hallym University Medical Center, Seoul, Korea. sismdps@chollian.net
2Department of Radiology, Kangnam Sacred Heart Hospital, Hallym University Medical Center, Seoul, Korea.
Abstract
PURPOSE
The purpose of this study is to demonstrate the usefulness of the high resolutional ultrasonographic features in patients with foreign body. METHODS: From September 2007 to August 2009, we retrospectively reviewed high resolutional ultrasonogram using 5~12MHz linear transducer of 13 patients presenting with inflammation after foreign body injection. They were referred for complications after foreign body injection. Injected foreign bodies were 4 silicone, 4 paraffin, 2 artecoll, and 3 unknown. We treated them with foreign body removal(7), foreign body removal and corrective plastic surgery(4), and conservative treatment with antibiotics and steroid injection(2).
RESULTS
High resolutional ultrasonography well demonstrated the existence of foreign body and it's overall size, location within the tissue layer, and vascularity. Comparison between preoperative and postoperative ultrasonographic findings was useful not only to evaluate the prognosis but also to plan the treatment. These ultrasonographic findings aided in precise assessment of the contour and location of the foreign body and led to an accurate surgery. We were able to acquire various information in order to set a detailed plan for the operation which in turn, led to a precise, successful surgery. After the treatment, complication did not occur in 12 patients, except 1 patient. But this patient was also treated after reoperation. Postoperative high resolutional ultrasonography shows almost foreign body removed and inflammation disappeared.
CONCLUSION
Considering the usefulness of high-resolution ultrasonography in foreign body injection, high-resolution ultrasonography would be necessary for both the patient and the doctor. Preoperative and postoperative high resolutional ultrasonography is highly accurate, safe, inexpensive and easy. It can be a useful modality in foreign body after plastic surgery.
Keywords: Foreign body; Inflammation; High-resolution ultrasonography
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1,226 View
  • 0 Download

Analysis of the Foreign Worker Patients in Plastic Surgery.2010 September;37(5)

Predictors of Readmission after Inpatient Plastic Surgery2014 March;41(2)



ABOUT
ARTICLE & SPECIALITY
Article category

Browse all articles >

Speciality

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-2003, Lotte Castle President, 109, Mapodaero, Mapo-gu, Seoul 04146, Korea
E-mail: apsedit@gmail.com                

Copyright © 2024 by Korean Society of Plastic and Reconstructive Surgeons.

Developed in M2PI

Close layer
prev next